CESK Bill of Quantities

CESK Bill of Quantities

Used with typical output information such as Bill of Quantities or Bill of Materials from engineering tools.

The CESK Bill of Quantities (BoQ) are a perfect match for cost estimators who want to efficiently translate detailed quantities into an accurate cost estimate, including costs for materials and labor.

The CESK BoQ dataset is developed to work in close harmony with the output from engineering design tools, such as BoQs and MTOs. Not only does the CESK BoQs allow for direct estimating of a wide range of disciplines, materials and sizes, it also incorporates information that is normally not included in a BoQ/MTO. For example, a piping MTO can be directly translated into a cost estimate of the piping materials included in that MTO, but also adds the related handling, supporting, testing and installation to your estimate. This means the estimator needs less time to prepare a complete cost estimate, leaving more time for optimizing and improving the quality of the overall estimate.

The CESK BoQs are also a perfect solution for estimating based on pipe specs, where the defined piping specifications can easily be matched to the corresponding BoQ rates.

Additional Information

Choose from the tabs below to view additional information about the CESK Bill of Quantities Dataset.

CONTENTS

Although piping is an important part of the CESK BoQ data, BoQ rates are also available for numerous other disciplines,

such as electrical, instrumentation and steel structures. These can be found in the overview below.

At the BOQ level, the civil knowledgebase is composed of different pre-defined structures. The composition of each structure includes the subcomponents: concrete, steel (rebar), and form work. The quantity of each subcomponent associated with each structure depends on its dimension and industry standards derived relations. When determining the quantities of the components at the BOQ level, the only information needed is the volume of concrete for the predefined structure.

Types
Basin
Beams
Block
Column footing
Columns
Octagon
Plint
Pour
Slabs
Tank wall
Pipe racks

Cables

Types Sub-types Ranges Installation methods
Earth cable Armoured 6-30kV 1,5 – 400 mm2 Supply and Install Above ground
Earth cable ZH Armoured Flex 1-37x Supply and Install Under ground
LV cable EMC Class 1, 2 & 5
LV cable EPR Flex EMC ea 16-95mm2
LV cable ZH Lead Armour
LV cable ZH 30/60 Non Arm
LV cable ZH 90 Wiring
MV cable

Cable support material

Types Sub-types Ranges Installation methods
Conduit HDG 50-1000mm Installed with support
Ladderrack PVC Installed without support
Tray SS316
Wire mesh tray

Heat tracing

Types Sub-types Ranges
Heat trace infrastructure Elbow -45 – 200 degrees
Self regulating cable Flange 1″ – 24″
Instrument 10 – 150mm insulation
Pipe
Pipe support
Pump
Tee
Valve

Junction boxes

Types Ranges Installation methods
Zone 2-3 3x-8x Installed on support
M20-M32
PG16 – PG21

Lighting

Types Sub-types Ranges Installation methods
Floodlight Closed 18-250W Fastened on wall or ceiling
Industrial Louvred Mounted on mast
Office Waterproof Mounted on support
Zone 1
Zone 2

BoQ-rates for equipment installation, including un-loading for Columns, Compressors, Heat exchangers, Pumps and Motors, Vessels, Skid units and packaged units.

Column

Ranges Installation locations
1,000 – 400,000 Install and unload

Compressor

Sub-types Ranges Installation locations
Centrifugal 0-300,000 Install and unload
Reciprocating Install and unload

Heat exchanger

Ranges Installation locations
1,000 – 125,000 Install and unload

Package unit

Ranges Installation locations
0-300,000 Install and unload

Pump + Motor

Ranges Installation locations
0-50,000 Install and unload

Trays & Internals

Sub-types Ranges Installation locations
Bubble cap tray 0 – 5,500 mm Install and unload
Chimney tray bolted
Chimney tray sealwelded
Demister package
Demister part of package
Distributor tray
Holddown grid
Liquid distributor
Random packing
Sieve tray
Structured packing
Support grid
Tray manway
Valve tray
Vapor distributor

Vessel

Sub-types Ranges Installation locations
Horizontal 0 – 400,000 Install and unload
Vertical

Coating and wrapping

Fittings, valves and pipes Installation locations
Elbow D=1/2″ – 48″
Flange cap DN 15 – 1200
Pipe
Valve cap

Insulation

Materials Fittings, valves and pipes Ranges Installation locations
Cold type (ALU) Elbow D=1/2″ – 48″ (Rem Insu + Sheet)
Cold type (SS) End cap DN 15 – 1200 (Rem+Re-use Insu)
Hot type (ALU) Equipment (Re-use Insu + Sheet)
Hot type (SS) Flange cap (Re-use Sheet + New Insu)
Pipe Thk = 30 – 140mm (New Insu + New Sheet)
Reducer (Rem & Re-use Insu + Sheet)
Tee (Rem & New Insu+ Rem & Re-use Sheet)
Valve cap (Rem & New Insu+ Rem & New Sheet)

Painting

Materials Fittings, valves and pipes Ranges Installation locations
-20 up to +120 °C, CS (m2) D=1/2″ – 48″ Painting + Blasting [SA2.5]+ X% Touch-up
>+120 up to +200 °C, CS Bend 45 DN 15 – 1200
>+200 up to +450 °C, CS Bend 90
Spec.Cap
-20 up to +120 °C, SS Elbow
>+120 up to +200 °C, SS Flange
Flange cap
Pipe
Reducer
Tee
Valve
Valve cap
Weld (field)

Piping (ASME)

Materials Fittings, valves and pipes Protection types Ranges Installation locations
Alloy20 Bellows Cold Insulated 150-3000# Install ISBL
CS Bending pipe Hot Insulated D= 1/2-48″ Install OSBL
CS GALV Bleed Ring Not protected Sch=5(S) – 160(S) Install Pipe rack
Duplex Bushing Painted
Hasteloy Cap Painted + Cold Insulated
LTCS Coupling Painted + Hot Insulated
SS304 Cross
SS316 Elbolet
Titanium Elbow
Flange
Hose
Lateral
Latrolet
Level Gauges
Nipolet
Nipple
Pipe
Plug
Quick coupling
Reducer Insert
Reducer
Sight Glass
Sockolet
Spacer
Spectacle blind
Steam trap
Strainer, Basket
Strainer, T
Strainer, Y
Stubend
Swage, Concentric
Swage, Eccentric
Tee
Test Blank
Threadolet
Union
Valve, Ball (Manual operated)
Valve, Butterfly (Manual operated)
Valve, Check
Valve, Diaphragm
Valve, ESD
Valve, Gate (Manual operated)
Valve, Globe (Manual operated)
Valve, Other
Valve, Relief
Weldolet

Piping (DIN)

Materials Fittings, valves and pipes Protection types Ranges Installation locations
1.4306 Cap Cold Insulated DN 15 – 1200mm Install ISBL
1.4404 Elbolet Hot Insulated PN10 – 400 Install OSBL
CS Elbow Not protected Wth = 1,4 – 65 mm Install Pipe rack
LTCS Flange Painted
Latrolet Painted + Cold Insulated
Nipolet Painted + Hot Insulated
Pipe
Reducer
Sockolet
Tee
Threadolet
Valve, Ball (Manual operated)
Valve, Butterfly (Manual operated)
Valve, Check
Valve, Gate (Manual operated)
Valve, Globe (Manual operated)
Weldolet

Piping (Plastic)

Materials Fittings, valves and pipes Protection types Ranges Installation locations
GRP Elbow 45 deg Not protected D = 20 – 500mm Electric weld socket connection
HDPE/PE Elbow 90 deg Hot insulated D=1/2″ – 20″ Glue connection
PVC Flange PN10 – 16 Laminate connection
Pipe Wth 2-29,4 Mirror weld
Reducer Stress resistant rubber connection
Tee

Piping (Plastic)

Materials Fittings, valves and pipes Protection types Ranges Installation locations
GRP Elbow 45 deg Not protected D = 20 – 500mm Electric weld socket connection
HDPE/PE Elbow 90 deg Hot insulated D=1/2″ – 20″ Glue connection
PVC Flange PN10 – 16 Laminate connection
Pipe Wth 2-29,4 Mirror weld
Reducer Stress resistant rubber connection
Tee

Cables

Types Sub-types
LV cable Armoured
LV cable EPR Armoured Flex
LV cable ZH EMC
LV cable ZH 30/60 Flex EMC
LV cable ZH 90 Lead Armour
Non Arm
Wiring

Cable support material

Types Sub-types Ranges Installation methods
Conduit HDG 50-1000mm Installed with support
Ladderrack PVC Installed without support
Tray SS316
Wire mesh tray

Control valves

Types Sub-types Ranges Installation methods
Ball valve Elecric actuated 1-24″ Installed with support
Butterfly valve Pneumatic actuated 150-600# Installed without support
Eccentric plug valve
Globe valve
Membrane valve
Segment ball valve

Flow instrument

Types Ranges Installation methods
Indicator 1-10″ Installed with support
Switch Installed without support
Transmitter

Instrument support

Types Ranges
On concrete floor 100-600mm
On steel floor
On unpaved floor
On pipe

Junction boxes

Types Sub-types Ranges Installation methods
EEXe Polyester 6-120 terminals Installed on support
SS316

Level instrument

Types Installation methods
Indicator Installed with support
Switch Installed without support
Transmitter radar
Transmitter remote seal
Transmitter ultrasonic

Pressure instrument

Types Installation methods
Controller Installed with support
Diaphragm gauge Installed without support
Diaphragm transmitter
Differential diaphragm gauge
Differential diaphragm transmitter
Differential gauge
Differential transmitter
Gauge
Indicator
Switch
Transmitter

Temperature instrument

Types Installation methods
Controller Installed with support
Element Installed without support
Gauge
Indicator
Switch
Transmitter
Transmitter RTD
Types Material Layers/Plates Sub-types
Ladders & platforms around CRV CS, HDG Double layer L = 4 – 36
Pipe rack CS, Painted Excl. Kickplate W = 0.5 – 8
Pipe rack model SS Single layer H = 4 – 12
Process structure Triple layer
Silo/Column structure With kickplate
T-support model
Walkway (side)
Walkway (top)

CESK Bill of Quantities can easily be integrated with Cleopatra Enterprise, the project cost management software.

If you want to know more about CESK composites and CESK data, please feel free to contact us.