CESK Bill of Quantities
CESK Bill of Quantities
Used with typical output information such as Bill of Quantities or Bill of Materials from engineering tools.
The CESK Bill of Quantities (BoQ) are a perfect match for cost estimators who want to efficiently translate detailed quantities into an accurate cost estimate, including costs for materials and labor.
The CESK BoQ dataset is developed to work in close harmony with the output from engineering design tools, such as BoQs and MTOs. Not only does the CESK BoQs allow for direct estimating of a wide range of disciplines, materials and sizes, it also incorporates information that is normally not included in a BoQ/MTO. For example, a piping MTO can be directly translated into a cost estimate of the piping materials included in that MTO, but also adds the related handling, supporting, testing and installation to your estimate. This means the estimator needs less time to prepare a complete cost estimate, leaving more time for optimizing and improving the quality of the overall estimate.
The CESK BoQs are also a perfect solution for estimating based on pipe specs, where the defined piping specifications can easily be matched to the corresponding BoQ rates.
Additional Information
Choose from the tabs below to view additional information about the CESK Bill of Quantities Dataset.
Although piping is an important part of the CESK BoQ data, BoQ rates are also available for numerous other disciplines,
such as electrical, instrumentation and steel structures. These can be found in the overview below.
-
Civil
At the BOQ level, the civil knowledgebase is composed of different pre-defined structures. The composition of each structure includes the subcomponents: concrete, steel (rebar), and form work. The quantity of each subcomponent associated with each structure depends on its dimension and industry standards derived relations. When determining the quantities of the components at the BOQ level, the only information needed is the volume of concrete for the predefined structure.
Types Basin Beams Block Column footing Columns Octagon Plint Pour Slabs Tank wall Pipe racks -
Electrical
-
Cables
Types Sub types Ranges Installation methods Earth cable Armoured 6-30kV 1,5 - 400 mm2 Supply and Install Above ground Earth cable ZH Armoured Flex 1-37x Supply and Install Under ground LV cable EMC Class 1, 2 & 5 LV cable EPR Flex EMC ea 16-95mm2 LV cable ZH Lead Armour LV cable ZH 30/60 Non Arm LV cable ZH 90 Wiring MV cable -
Cable support material
Types Sub types Ranges Installation methods Conduit HDG 50-1000mm Installed with support Ladderrack PVC Installed without support Tray SS316 Wire mesh tray -
Heat tracing
Types Sub types Ranges Heat trace infrastructure Elbow -45 - 200 degrees Self regulating cable Flange 1" - 24" Instrument 10 - 150mm insulation Pipe Pipe support Pump Tee Valve -
Junction boxes
Types Ranges Installation methods Zone 2-3 3x-8x Installed on support M20-M32 PG16 - PG21 -
Lighting
Types Sub types Ranges Installation methods Floodlight Closed 18-250W Fastened on wall or ceiling Industrial Louvred Mounted on mast Office Waterproof Mounted on support Zone 1 Zone 2
-
-
Equipment Installation
BoQ-rates for equipment installation, including un-loading for Columns, Compressors, Heat exchangers, Pumps and Motors, Vessels, Skid units and packaged units.
-
Column
Ranges Installation locations 1,000 - 400,000 Install and unload -
Compressor
Sub types Ranges Installation locations Centrifugal 0-300,000 Install and unload Reciprocating Install and unload -
Heat exchanger
Ranges Installation locations 1,000 - 125,000 Install and unload -
Package unit
Ranges Installation locations 0-300,000 Install and unload -
Pump + Motor
Ranges Installation locations 0-50,000 Install and unload -
Trays & Internals
Sub types Ranges Installation locations Bubble cap tray 0 - 5,500 mm Install and unload Chimney tray bolted Chimney tray sealwelded Demister package Demister part of package Distributor tray Holddown grid Liquid distributor Random packing Sieve tray Structured packing Support grid Tray manway Valve tray Vapor distributor -
Vessel
Sub types Ranges Installation locations Horizontal 0 - 400,000 Install and unload Vertical
-
-
Piping, Insulation, Painting, Coating & Wrapping
-
Coating and wrapping
Fittings, valves and pipes Installation locations Elbow D=1/2" - 48" Flange cap DN 15 - 1200 Pipe Valve cap -
Insulation
Materials Fittings, valves and pipes Ranges Installation locations Cold type (ALU) Elbow D=1/2" - 48" (Rem Insu + Sheet) Cold type (SS) End cap DN 15 - 1200 (Rem+Re-use Insu) Hot type (ALU) Equipment (Re-use Insu + Sheet) Hot type (SS) Flange cap (Re-use Sheet + New Insu) Pipe Thk = 30 - 140mm (New Insu + New Sheet) Reducer (Rem & Re-use Insu + Sheet) Tee (Rem & New Insu+ Rem & Re-use Sheet) Valve cap (Rem & New Insu+ Rem & New Sheet) -
Painting
Materials Fittings, valves and pipes Ranges Installation locations -20 up to +120 °C, CS (m2) D=1/2" - 48" Painting + Blasting [SA2.5]+ X% Touch-up >+120 up to +200 °C, CS Bend 45 DN 15 - 1200 >+200 up to +450 °C, CS Bend 90 Spec. <60 Deg.; SS Cap -20 up to +120 °C, SS Elbow >+120 up to +200 °C, SS Flange Flange cap Pipe Reducer Tee Valve Valve cap Weld (field) -
Piping (ASME)
Materials Fittings, valves and pipes Protection types Ranges Installation locations Alloy20 Bellows Cold Insulated 150-3000# Install ISBL CS Bending pipe Hot Insulated D= 1/2-48" Install OSBL CS GALV Bleed Ring Not protected Sch=5(S) - 160(S) Install Pipe rack Duplex Bushing Painted Hasteloy Cap Painted + Cold Insulated LTCS Coupling Painted + Hot Insulated SS304 Cross SS316 Elbolet Titanium Elbow Flange Hose Lateral Latrolet Level Gauges Nipolet Nipple Pipe Plug Quick coupling Reducer Insert Reducer Sight Glass Sockolet Spacer Spectacle blind Steam trap Strainer, Basket Strainer, T Strainer, Y Stubend Swage, Concentric Swage, Eccentric Tee Test Blank Threadolet Union Valve, Ball (Manual operated) Valve, Butterfly (Manual operated) Valve, Check Valve, Diaphragm Valve, ESD Valve, Gate (Manual operated) Valve, Globe (Manual operated) Valve, Other Valve, Relief Weldolet -
Piping (DIN)
Materials Fittings, valves and pipes Protection types Ranges Installation locations 1.4306 Cap Cold Insulated DN 15 - 1200mm Install ISBL 1.4404 Elbolet Hot Insulated PN10 - 400 Install OSBL CS Elbow Not protected Wth = 1,4 - 65 mm Install Pipe rack LTCS Flange Painted Latrolet Painted + Cold Insulated Nipolet Painted + Hot Insulated Pipe Reducer Sockolet Tee Threadolet Valve, Ball (Manual operated) Valve, Butterfly (Manual operated) Valve, Check Valve, Gate (Manual operated) Valve, Globe (Manual operated) Weldolet -
Piping (Plastic)
Materials Fittings, valves and pipes Protection types Ranges Installation locations GRP Elbow 45 deg Not protected D = 20 - 500mm Electric weld socket connection HDPE/PE Elbow 90 deg Hot insulated D=1/2" - 20" Glue connection PVC Flange PN10 - 16 Laminate connection Pipe Wth 2-29,4 Mirror weld Reducer Stress resistant rubber connection Tee -
Piping (Plastic)
Materials Fittings, valves and pipes Protection types Ranges Installation locations GRP Elbow 45 deg Not protected D = 20 - 500mm Electric weld socket connection HDPE/PE Elbow 90 deg Hot insulated D=1/2" - 20" Glue connection PVC Flange PN10 - 16 Laminate connection Pipe Wth 2-29,4 Mirror weld Reducer Stress resistant rubber connection Tee
-
-
Instrumentation
-
Cables
Types Sub types LV cable Armoured LV cable EPR Armoured Flex LV cable ZH EMC LV cable ZH 30/60 Flex EMC LV cable ZH 90 Lead Armour Non Arm Wiring -
Cable support material
Types Sub types Ranges Installation methods Conduit HDG 50-1000mm Installed with support Ladderrack PVC Installed without support Tray SS316 Wire mesh tray -
Control valves
Types Sub types Ranges Installation methods Ball valve Elecric actuated 1-24" Installed with support Butterfly valve Pneumatic actuated 150-600# Installed without support Eccentric plug valve Globe valve Membrane valve Segment ball valve -
Flow instrument
Types Ranges Installation methods Indicator 1-10" Installed with support Switch Installed without support Transmitter -
Instrument supports
Types Ranges On concrete floor 100-600mm On steel floor On unpaved floor On pipe -
Junction boxes
Types Sub types Ranges Installation methods EEXe Polyester 6-120 terminals Installed on support SS316 -
Level instrument
Types Installation methods Indicator Installed with support Switch Installed without support Transmitter radar Transmitter remote seal Transmitter ultrasonic -
Pressure instrument
Types Installation methods Controller Installed with support Diaphragm gauge Installed without support Diaphragm transmitter Differential diaphragm gauge Differential diaphragm transmitter Differential gauge Differential transmitter Gauge Indicator Switch Transmitter -
Temperature instrument
Types Installation methods Controller Installed with support Element Installed without support Gauge Indicator Switch Transmitter Transmitter RTD
-
-
Structural
Types Pipe racks